EC to TDS Converter

Enter EC in µS/cm to estimate TDS in ppm. Adjust the conversion factor for your water type.

µS/cm
Quick values:
factor
Common factors:
TDS = EC × factor
300 ppm
600 µS/cm
×
0.5 Factor
=
300 ppm

What is the EC to TDS Converter?

Estimate total dissolved solids (TDS, in ppm) from an electrical conductivity (EC) reading in µS/cm.

The EC to TDS Converter estimates the total dissolved solids of a water sample from its electrical conductivity using the relation TDS = EC × factor. Because conductivity rises predictably as dissolved ion content increases, an EC reading serves as a fast proxy for TDS — no evaporation or weighing required. Selecting the right factor for your salt profile (about 0.5 for NaCl-type waters, up to 0.7 for others) makes the estimate more accurate.

Electrical conductivity (EC), measured in microsiemens per centimeter (µS/cm), quantifies how well water conducts electricity, which depends on the concentration and mobility of its dissolved ions. Total dissolved solids (TDS) is the mass of those dissolved minerals and salts, expressed in parts per million (ppm) — effectively milligrams per liter for water. EC is what a meter actually measures; TDS is the quantity most guidelines and product specifications are written in.

This is the everyday conversion behind most handheld TDS meters, which measure EC internally and display a converted TDS value. It is used to judge drinking-water quality (palatability and scaling potential), to manage nutrient strength in hydroponics, and to monitor water conditions in aquaculture, where both fish health and feeding regimes depend on stable dissolved mineral levels.

How the Conversion Works

To convert EC to TDS, apply 3 steps: record the EC reading in µS/cm, select the conversion factor for your water, and read the estimated TDS.

01

Record the EC Reading

Note Electrical Conductivity in microsiemens per centimeter, ideally temperature-compensated to 25 °C. Conductivity rises about 2% per °C, so uncompensated readings skew the TDS estimate.

EC ≈ +2% per °C
02

Select the Conversion Factor

Pick the factor for your water type: 0.5 for NaCl-type water, 0.64 for mixed municipal water, or 0.7 for the 442 standard. Most handheld TDS meters apply one of these factors internally.

TDS = EC × factor
03

Read TDS in PPM

The result estimates Total Dissolved Solids in ppm (mg/L) — the figure used on drinking-water quality reports, reverse-osmosis specifications, and aquarium guidelines.

600 µS/cm × 0.5 = 300 ppm

Conversion Formula

To convert Electrical Conductivity (EC) to Total Dissolved Solids (TDS), multiply the EC value in µS/cm by the conversion factor.

EC to TDS Conversion Formula

TDS = EC × factor
EC (µS/cm) × factor
= TDS (ppm)
→
600 × 0.5
= 300 ppm

The EC to TDS conversion formula is TDS (ppm) = EC (µS/cm) × conversion factor. Conductivity meters measure how easily current flows between two electrodes; multiplying by the empirical factor translates that electrical reading into an estimated dissolved-solids mass.

Handheld TDS meters are really EC meters with a fixed factor — commonly 0.5 or 0.7 — built in. Reverse-osmosis installers, aquarium hobbyists, and well owners use this conversion to judge filter performance and water acceptability; the U.S. EPA secondary drinking-water standard is 500 ppm TDS.

Frequently Asked Questions

6 answers to the most common questions about EC to TDS conversion.

TDS (ppm) = EC (µS/cm) × conversion factor. For example, 600 µS/cm × 0.5 = 300 ppm TDS. The factor is chosen to match the dominant salts in the water.

Match the factor to the dominant salts: 0.5 for sodium-chloride-type water, about 0.64 for typical mixed municipal supplies, and 0.7 for water resembling the 442 calibration standard.

If your meter applies a fixed internal factor, use the same value here so this calculator agrees with the TDS figure your meter displays.

No — handheld TDS meters measure electrical conductivity and multiply it by a built-in factor. True TDS requires evaporating a weighed sample in a laboratory. For everyday monitoring, the meter estimate is perfectly adequate.
Typical tap water reads 50–500 ppm TDS (100–1,000 µS/cm). The U.S. EPA secondary (aesthetic) standard is 500 ppm; water below about 600 ppm generally tastes good, while the WHO notes palatability declines above 1,000 ppm.
Yes — conductivity rises roughly 2% per °C. Quality meters apply automatic temperature compensation to a 25 °C reference. Always compare temperature-compensated readings, otherwise the TDS estimate drifts with the sample temperature.
At very high concentrations or with unusual ionic mixes — industrial effluents, brines, or produced water — the linear factor breaks down. For regulatory or process-critical decisions, confirm with a laboratory gravimetric TDS analysis.